Ubibot insists on researching and developing self-owned patent products, including the external probes that match our sensing devices.
There are three types of probes that can match with the WS1 and WS1 Pro device. Here are the instructions of how to use them.
Using WS1 device:
This device supports DS18B20 probe. As it only has one USB port, only one probe can be connected. When using USB power at the same time, one USB splitter is needed. Connect the splitter to the device USB port, one female port is for power and the other is for data transmission.
Using WS1 Pro device:
This device supports DS18B20, TH30s-B, Soil temperature and moisture sensor, and PT-100 extreme temperature probe.
It has two USB ports, of which the lower one is embedded with RS485 interface. Except the DS18B20 probe, the others both need to be connected to this lower USB port. While, you can use DS18B20 on either of the USB port. When you need to power the device via Micro USB and you want to connect more than two probes at the same time, please remember, the ends of the splitter must be connected with one power supply and one probe, or one DS18B20 and one RS485 probe. Two same probes are not supported on one port.
Using GS1 device:
The GS1 device is built with RS485 interface and audio jack. It supports all of the 6 types of Ubibot probes, such as TH30S-B temperature humidity probe, Soil moisture probe, PT-100 temperature probe, CO2 probe, wind speed probe, external light probe.
If you only need one type probe, you can connect it to the device directly. If you need more than one type, our splitters will allow you to attach multiple probes simultaneously. Please see the following cutline for reference. Please note, only one piece of probe of each type is supported. You can not attach two or more of the same probes at a time. And, the TH30S-B probe and CO2 probe can not be used simultaneously.
*Note, the probes are under one year limited warranty since the purchase date. For details, please click here.
Comments
4 comments
I have 4 Ubibot WS-1 units. 2 units have external temperature probes.
I have trouble keeping these probes connected to the UbiBot Control panel.
They will show a past temperature but are grayed out. If I unplug and replug
in the probe becomes active, however only for a short time. Is there a resolution
to this? mwdavis76@gmail.com
Me also.
I have the same problem, the temperature and humidity probe RS485 are grayed out. One unit shows a past temperature and the other unit shows me 0%
After even buying and replacing a probe due to this, I found the solution somewhere in settings.
It's been awhile but look under Device Management or Data Management when you are in a device. Make sure the switches are set to yes that should be.